GREEN TEAM View CartCheckout  | About Us | . | What are we talking about? Cheap Fuel? | Wholesale Bulk Orders 
Home
Filter Housings
Bags & Bucket
Elements
Pipe parts
Pumps
Hose Pipes
Chemicals
HHO
Ibc, Tank & Drums
Processor Parts
Titration
Search

Shopping Cart
ItemQtyPrice

Sub Total: £0.00
Delivery: £0.00
Total: £0.00

Select Currency
Australian DollarCanadian DollarSwiss FrancDanish KroneEuroPound SterlingNorwegian KroneUS Dollar


Your Account
Forgotten your password? Click here

Newsletter Signup

complete starter kit

please see the offer under Filter Housings

.

..

.


Categories
IPA - Isopropyl Alcohol
pH Testing Equipment - Paper and Pen Holders
Scales
Syringes and Pipettes
Titration Equipment & General Lab Equipment
  Home > Titration >

EQUIPMENT IS BELOW THIS TITRATION METHOD.

INTRODUCTION
One of the most common questions beginning biodieseler's have is how to perform a titration. When I first learned about Biodiesel, I was taught a really easy way to do titrations. I tried a few other methods but I keep coming back to this one because of how simple it is. It's really easy to do and makes titrating the oil really simple.

Why Do A Titration?
Titration is just a fancy word for the process used to find out how much catalyst will be needed to make biodiesel out of waste vegetable oil. The catalyst I use is called Potassium Hydroxide (KOH), also known as Caustic Potash. You can also substitute Sodium Hydroxide (NaOH), also known as Lye, in place of the Potassium Hydroxide. You'll want to titrate using the same catalyst that you'll be using when you make your biodiesel.

The "nuts & bolts" of what's going on during a titration is nothing more than seeing how much of a base it's going to take to neutralize the free fatty acids in a sample of the oil you'll be using to make biodiesel. We use a PH indicator called Phenol Red or Phenolphthalien. .

Materials Needed
1- (3) small bowls that can hold at least 50 ml of liquid
2- (3) small syringes that are metered in 1 ml increments up to 10 ml
3- (1) pint of 91% Isopropyl Alcohol
4- (1) gallon of distilled water
5- (1) gram of Potassium Hydroxide (KOH) or Sodium Hydroxide (NaOH)
6- Either Phenol Red or Phenolphthalien (both will work)
7- A sealable container that can hold at least 1 liter of liquid
8- A scale that can measure down to .05 of a gram

TITRATION INSTRUCTIONS

Create A Stock Testing Solution
This will create a testing solution that can be used for each titration.
1- Add 1 Liter of Distilled Water to the 1 Liter container
2- Add 1 gram of KOH or NaOH to the 1 liter container
3- Shake the solution around until all of the KOH dissolves
4- Label the container TITRATION SOLUTION
NOTE: About every 90 days, remake this solution as it does "expire".

Label The Bowls
Bowl 1- Titration Solution
Bowl 2- Alcohol
Bowl 3- Titration

Prepare The Bowls
1- Pour about 30 mL of Titration Solution into Bowl #1
2- Pour about 20 mL of Isopropyl Alcohol into Bowl #2

Prepare Titration Bowl
1- Add 1 mL of oil to Bowl #3
2- Add 10 mL of Isopropyl Alcohol from Bowl #2 to Bowl #3
3- Mix the oil & alcohol together until it's a consistent solution
(sometimes heating the bowl will help it mix together)
4- Add 4 drops of Phenol Red or Phenolphthalien to Bowl #3

The Actual Titration Process
1- Suck up 10 mL of testing solution into a syringe from Bowl #1
2- Drop a drop of testing solution into Bowl #3, watching for a color change each time
3- Hold the bowl in your hand and swirl the solution around for 30 seconds
4- If the color change goes way, add another drop of solution from the syringe
5- Repeat steps 2-4 until the color change stay's for at least 30 seconds
6- Record on a peice of paper how many mL of solution you put in Bowl #3 to keep the color change.

The Titration Calculation
If you're using KOH (Potassium Hydroxide) in the titration solution
-Add 7 to the result from step 1
If you're using NaOH (Sodium Hydroxide) in the titration solution
-Add 5.5 to the result from step 1
2- The result will be how many grams of catalyst you'll use per liter of oil.

Example:
100 liters of oil to be converted to biodiesel
It titrated to 4
If KOH, add 7 + 4 = 11 grams/liter X 100 liters = 1100 Grams
If NaOH, add 5.5 + 4 = 9.5 grams/liter X 100 liters = 950 grams
Add 1100 grams of KOH or 950 grams of NaOH to the methanol to make biodiesel using this oil.

Accounting For Catalyst Purity
In most cases it will be difficult to find 100% pure KOH or NaOH. Here's how to account for that. Simply divide the "BASE" by the purity. If KOH is used and it's 90% pure, then divide 7 by .90 (7/.90 = 7.8)
If NaOH is used and it's 95% pure, then divide 5.5 by .95 (5.5/.95 = 5.8)
Now, instead of using 7 or 5.5, use the "corrected" numbers to calculate how much catalyst is needed.

ADDITIONAL COMMENTS
It's recommended to do a titration 3 times and record the three results. If the results are close (+/- 1), then you're set. If it's way off, you'll want to repeat the titrations ensuring that you follow the steps exactly until your results are close.

Also, only use each syringe for one purpose. For example, use one syringe for oil only, use a separate syringe for the titration solution, and another separate syringe for the alcohol. If you mix them it can cause inaccurate titrations.

Titrating Oil To Make Biodiesel
by Graydon Blair

Online Titration Calculators
These sites offer online titration calculators to help with calculating titrations.
Extreme Biodiesel Titration Calculator One of the best online!

IPA - Isopropyl AlcoholIPA - Isopropyl Alcohol
Various sizes available from 500ml to 25 litres.
pH Testing Equipment - Paper and Pen HolderspH Testing Equipment - Paper and Pen Holders
Various papers (litmus) for testing. Also includes buffer solutions and Pen Style Testing Ph Levels
ScalesScales
Syringes and PipettesSyringes and Pipettes
Titration Equipment & General Lab EquipmentTitration Equipment & General Lab Equipment
inc Phenol Red, Beakers and large selection of pieces inc lab coats and utensils

« Back

all prices

include vat


Contact Us

Email

click here


Special Offers
Biodiesel B100 Road Use
Tam105 Clarke Pump
IBC pre used non chemicals
10 inch slim Filter housings 3/4" ports clear
Wash bottle - choice of chemical named bottles 500ml
Runback Timer 0-30 minutes or a 0-120 minutes
Complete Starter Kit - everything you need included
Starters Pack - 10" Housing, 2x Elements, 1x Spanner


all prices include vat


Site Map | Terms & Conditions
copyright Green Team 2009